Search results for "Non ionic"
showing 5 items of 5 documents
Compatibility of epirubicin-loaded DC bead™ with different non-ionic contrast media
2016
Purpose The aim of this study was to determine the compatibility of epirubicin-loaded DC bead™ with different non-ionic contrast media over a period of seven days when stored light protected under refrigerated conditions. Methods DC bead™ (2 ml) (Biocompatibles UK Ltd) of the bead size 70–150 µm ( = DC bead M1) or bead size 100–300 µm were loaded with 75 mg epirubicin powder formulation (Farmorubicin® dissolved in 3 ml water for injection to a concentration of 25 mg/ml) or 76 mg epirubicin injection solution (Epimedac® 2 mg/ml) within 2 h or 6 h, respectively. After removal of the excess solution, the epirubicin-loaded beads were mixed in polypropylene syringes with an equal volume (∼1.5 ml…
Quantitative structure-retention relationships for ionic and non-ionic compounds in biopartitioning micellar chromatography
2004
Quantitative structure–retention relationships, QSRRs, represent a powerful tool in chromatography. The objectives of QSRR studies are to predict the chromatographic retention behaviour of solutes based on their structural properties, to elucidate retention mechanisms, to optimize the separation of complex mixtures or to prepare experimental designs. In this paper, using the retention factors of 151 structurally unrelated solutes that cover a wide range of hydrophobicity, molecular size, hydrogen bonding properties and ionization degrees obtained in biopartitioning micellar chromatography (BMC) at different Brij35 micellar concentrations, several multivariate QSRR models are tested. It is d…
Dynamic evolution of the oscillatory Belousov-Zhabotinsky reaction upon addition of a non-ionic polymer
2006
Abstract The dynamic evolution of the oscillatory Belousov–Zhabotinsky reaction upon addition of increasing amount of the non-ionic polymer polypropylene glycol with molecular weight 425 g mol−1 (PPG-425) was investigated in a stirred-batch reactor by monitoring the Ce(IV) absorbance changes. The oscillatory parameters are significantly altered by the presence of the polymer. The findings obtained in the present work revealed that the PPG-425 is not only more effective, than other polymer previously [R. Lombardo, C. Sbriziolo, M.L. Turco Liveri, K. Pelle, M. Wittmann, Z. Noszticzius, in: J.A. Pojman, Q. Tran-Cong-Miyata (Eds.), Nonlinear Dynamics in Polymeric Systems, American Chemical Soci…
Compatibility of irinotecan-loaded DC Bead with different volumes and types of non-ionic contrast media.
2015
Objectives Irinotecan-loaded microspheres are used for simultaneous embolisation and chemotherapy of liver metastases of colorectal carcinoma. The aim of the study was to evaluate the compatibility of recently introduced DC Bead M1 (bead size 70–150 µm) loaded with irinotecan after admixture with different types and volumes of non-ionic contrast media over a maximum period of 24 h and storage at room temperature. Methods Test suspensions were prepared by loading 2 mL DC Bead M1 with 100 mg irinotecan within 2 h. The loading efficiency was determined by measuring the concentrations of irinotecan in the excess solutions via a reversed phase high pressure liquid chromatography (RP-HPLC) assay …
Clay/Non-Ionic Surfactant Hybrid Nanocomposites
2020
This chapter gives an overview of the structural and chemical physical properties of nanocomposites formed by clay minerals and surfactants, which represent a class of materials with promising features for applications in different industrial, biomedical, and environmental applications. Due to their non-toxicity and biocompatibility, a great deal of attention is nowadays devoted to the study of non-ionic surfactants. Among them, block copolymers represent a combination of the properties of common amphiphilic molecules and long polymer chains. These macromolecules can form a great variety of supra-molecular structures generated from self-organization phenomena in aqueous media. Nanostructure…